Whole-home duct cleaning
Dryer vent cleaning
Camera inspection
Sanitizing & deodorizingWhole-system duct and dryer vent check with before-and-after photos - you see exactly what came out of your vents
That "$99 whole-house special" is a bait ad - the real number appears once they are in your hallway, or the "clean" is a shop-vac at the register. We photograph the inside of your ducts before and after instead.
Guardsman Vent Sanitizing: The Henderson Owner’s Guide
We stock and install Guardsman-compatible vent sanitizing components for Henderson homes, and most replacements run between $220 and $480 installed depending on your system’s age and access. The typical job takes under two hours, and our trucks carry the common Guardsman sanitizer cartridges, UV bulb replacements, and mounting hardware so we’re not making you wait on a parts order. What usually brings Henderson homeowners to this page is simple: the sanitizing light has gone out, the unit’s making a faint buzzing, or airflow past the sanitizer just doesn’t smell clean anymore.
A quick note on terms: when we say “vent sanitizing” in the Guardsman context, we’re talking about the inline UV sanitizer or cartridge system mounted in the supply plenum near the air handler. It’s not a filter, and it’s not the ducts themselves. It’s the component that treats air as it leaves the blower, and when it fails, you lose that layer of microbial control entirely.
One thing worth saying up front: Hollis Air Duct Henderson is an independent service provider, not affiliated with Guardsman. We install and service Guardsman products because Henderson homes have a lot of them and they’re built well. We stock OEM Guardsman parts where it matters and quality aftermarket equivalents where the specs line up.
Which Guardsman Models This Applies To
The Guardsman vent sanitizing lineup splits into two families: the UV-C stick light models (the ones that look like a fluorescent tube in a metal housing) and the RCI/PHI cartridge models that mount flush in the plenum. Both are common in Henderson, but they take entirely different replacement parts, so the first thing we do is identify what you actually have. The model number is usually printed on a label on the housing or stamped on the ballast.
The UV stick lights fail at the bulb or the ballast, and Guardsman changed bulb pin configurations across their series line, so a bulb from 2014 may not fit a housing from 2021. The cartridge models fail at the cell itself, and the draw they put on your system changes as the cell degrades. We check the system’s static pressure before and after a cartridge swap because a clogged or degraded cell can add resistance your blower’s been fighting for months.
For OEM versus aftermarket: on the RCI-style cells, we recommend OEM. The cell chemistry and the housing tolerances are tight, and the aftermarket versions we’ve pulled out of Henderson systems have been a mixed bag. On UV bulbs, there are a couple of quality aftermarket brands we stock on the truck that hold up fine, and we’ll tell you the brand and the spec before we install anything.
Compatibility gotcha to know: Guardsman units sold through HVAC contractors in the Southwest often shipped with a different ballast than the retail versions, so the replacement bulb that looks identical on the shelf may not fire. We match by the ballast’s input voltage and lamp wattage, not just by bulb length.
Styles & brands we work with




Signs Your Guardsman Vent Sanitizing Is Failing
- The indicator light is out or flickering. On UV models, this almost always means the bulb has reached the end of its rated life (typically 9,000 to 16,000 hours, or roughly one to two years of continuous run time) or the ballast is failing. A dead bulb means the sanitizer is just a metal sleeve in your duct doing nothing.
- You smell ozone. RCI-style cell models produce controlled amounts of ozone as part of the oxidation process. When a cell is going bad, the output can spike, and you’ll catch a sharp, almost electrical smell near a supply register. That’s a sign the cell needs replacement, not a reason to unplug it forever.
- Airflow out of the registers seems weaker. A degrading or dust-caked RCI cell adds resistance inside the plenum. Henderson’s dry air and the fine dust that moves through systems near the McCullough Range can coat a cell faster than the manufacturer’s average timeline, reducing its effectiveness and forcing your blower to work harder.
- You replaced the bulb less than a year ago and it’s already out. Short bulb life usually means a ballast that’s been running hot, or a power issue inside the unit. Swapping bulbs on repeat is throwing money at the symptom while the cause is still in there.
- The system runs but allergies or stale-air complaints are back. This is the one people write off as coincidence. It’s not. The sanitizer was masking a load that’s now moving through your ducts untreated.
See the difference
Before
After
Before
After
Before
AfterReplacement Cost & What’s Included
In Henderson, a Guardsman UV bulb replacement runs $220 to $310 installed. A full RCI or PHI cell replacement lands between $340 and $480. The range comes down to your specific model, how accessible the plenum is, and whether the ballast or mounting hardware needs attention while we’re there. We write the price before we touch the work, and that price doesn’t move once we’re on site.
Every replacement includes a full check of the sanitizer housing, the electrical connections, and a static pressure reading to verify the new part isn’t choking your airflow. The part itself carries the manufacturer’s warranty, and our labor carries the 365-Day Done Right Promise: if the install fails within a year, we come back and make it right at no charge. That’s in writing, every job.
What we won’t do is hand you a per-part price without seeing your unit, because the wrong part at a low price is still a waste of your money. Call us with your model number and we’ll tell you over the phone what the installed range looks like for your specific setup.
DIY or Call Us?
This one needs the straight answer up front: a Guardsman vent sanitizer operates on line voltage, and it’s mounted inside your air handler’s plenum. That means electrical exposure and sheet metal work. If you’re comfortable working inside a live panel and you know how to kill power at the disconnect and verify it’s dead, replacing a UV bulb is within reach. Beyond the bulb, we recommend a trained technician.
What you can safely check yourself: find the model number, note whether the indicator light is on, and listen for buzzing at the ballast. That information helps us quote the right part before we arrive. What goes wrong with DIY on these units in Henderson is usually the same story: someone buys a universal bulb that doesn’t match the ballast, or they crack the quartz sleeve during install and don’t realize it until the unit shorts. Roy Castellanos runs a methodical inspection on every sanitizer call before any work starts, because a blower pushing air through a system that hasn’t been mapped first just moves the problem around. If you can’t explain what you’re doing and why, you probably shouldn’t be doing it.
FAQs
Plan on 12 to 18 months of continuous run time, not the two-year figure on the box. Henderson’s heat cycle means your blower runs long hours through the summer, and the fine dust moving through systems near the foothills coats bulbs faster than the manufacturer’s lab conditions. We see a lot of bulbs that technically still light at 18 months but have lost enough UV output to be ineffective. Budget for replacement every 1 to 1.5 years, and call (775) 383-5847 if you’ve lost track of when it was last done.
Ballasts can be replaced independently of a bulb, and a quartz sleeve can be cleaned or swapped without touching the cell. But for the RCI/PHI cells, when the cell degrades, it’s a replacement part, not a repair. Either way, the work needs to be done by someone who can test the system’s output afterward. Call us and we’ll tell you honestly if a repair makes sense before you spend money on a full replacement.
Most Guardsman swaps in Henderson take 60 to 90 minutes from arrival to a clean work area. Add 10 minutes if we need to modify the access panel. You don’t need to be home for the entire appointment, but someone over 18 needs to be present.
Yes. Our trucks carry the common Guardsman UV bulbs, ballasts, and RCI-style cells for the models we see most in Henderson, along with equivalent parts for Lennox, Trane, and Carrier systems. If your unit takes something outside that, we order it and return to install typically within a few business days, with the full price still in writing before any work begins.
If your Guardsman vent sanitizer is out, making noise, or you just can’t remember the last time anyone looked at it, call (775) 383-5847 for a free estimate. We’ll get you a real price, in writing, before any work starts. No pressure, no moving targets.
Written by Roy Castellanos, Owner, Hollis Air Duct Henderson at Hollis Air Duct Henderson, serving Henderson and nearby areas.